File #: ID 18-0435    Version: 1 Name: Forcemain Condition Assesment
Type: Resolution Status: Passed
File created: 6/25/2018 In control: City Council
On agenda: 7/17/2018 Final action: 7/17/2018
Title: Resolution Approving a Contract with Arcadis G&M of North Carolina, Inc. to perform Force Main Condition Services
Indexes: All Districts, WR Contracts
Attachments: 1. Arcadis Secretary of State.pdf, 2. H-NB-BD Forcemain Condition Assessment Rev1.asd.pdf, 3. MWBE Sewer Force Main Condition Assessments-MWBE Memo.pdf, 4. 18-0435 Resolution Force Main Condition Assessment Services.pdf

Title
Resolution Approving a Contract with Arcadis G&M of North Carolina, Inc. to perform Force Main Condition Services

Body
Department: Water Resources
Council District: All

Public Hearing: N/A
Advertising Date/By: N/A

Contact 1 and Phone: Steven D. Drew, 373-7893
Contact 2 and Phone: Kristine Williams 373-2556

PURPOSE:
The Water Resources Department is requesting approval to enter into a professional services contract with Arcadis G&M of North Carolina, Inc. to provide force main condition services to investigate critical force mains in the City's sanitary sewer system.

BACKGROUND:
The professional services of Arcadis G&M of North Carolina, Inc. will be utilized to continue with the City's asset management program to investigate the condition of its critical assets that pose significant risk to the environment and public if a failure were to occur. The project will assess condition and will support decision-making for future work to repair, replace, or rehabilitate these assets.

Arcadis G&M of North Carolina, Inc. will utilize ultrasonic and broadband electro-magnetic technologies to collect assessment data and analyze force main condition data for recommendations to support City staff with the decision-making process on whether these critical assets should be repaired, replaced, rehabilitated, or monitored further. The force mains that will be assessed include Horse Pen Creek, the North Buffalo Transfer main, and Bledsoe force main. The force mains are critical assets with a high likelihood for failure based on age, historical break data, and operational data. Furthermore, these force mains have high consequences of failure because of the location of the force mains and lack of redundancy.

Arcadis G&M of North Carolina, Inc., an on-call consultant with the Water Resources Department was selected for this project based on their experience and success in providing sanitary sewer projects for the Department and for their expertise in condition ass...